Resistance: | Fixed Resistor |
---|---|
Function for Resistance: | Protective Resistor |
Material: | Wire-wound Resistor |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Cement Type Resistor (wire wound) |
||||||||||||||||
Characteristics |
Specifications |
Test Method |
||||||||||||||
DC Resistance JIS-C-5202 5.1 |
J ± 5% |
AT 25° C |
||||||||||||||
Dielectric withstanding voltage JIS-C-5202 5.7 |
No evidence of flashover mechanical amage, arcing or insulation breakdown. |
Resistance shall be clamped with a conductive material which conforms to resistors surface so that 90 o of the outer periphery is contacted a potential of 1000V AC shall be applied for 60 seconds. |
||||||||||||||
Insulation Resistance JIS-C-5202 5.6 |
1000MΩ MIN |
Withstanding test and shall be measured at DC 500V. Resistor shall be prepared AC same method of dielectric. |
||||||||||||||
Thermal Shock |
Δ R≤ ± (2%R 0 +0.1Ω ) |
After application of rated power for 30 minutes, 30 minutes exposure to -30± 5° C ambient temperature. |
||||||||||||||
Humidity JIS-C-5202 7.5 |
Δ R≤ ± (2%R 0 +0.1Ω ) |
Temperature resistance change after 1000 hours exposure in a humidity test chamber controlled at 40± 2° C and 90~95% relative humidity. |
||||||||||||||
Cement Type Resistor (metal oxide film) |
||||||||||||||||
Short time overload |
Δ R≤ ± (2%R 0 +0.05Ω ) |
Temperature resistance change after the application of a potential of 2.5 times RCVW for 5 seconds. |
||||||||||||||
Load Life JIS-C-5202 7.10 |
Δ R≤ ± (5%R 0 +0.1Ω ) |
Permanent resistance change after 1000 hours operating at RCWV, with duty cycle of 1.5 hours on and 0.5 hours off at 25° C± 2° C. |
||||||||||||||
Load Life in Humidity JIS-C-5202 7.9 |
Δ R≤ ± (5%R 0 +0.1Ω ) |
Temperature resistance change after 1000 hours(1.5hours on and 0.5 hours off) at RCVW in a humidity chamber controlled at 40± 2° C and 90~95% relative humidity. |
||||||||||||||
Solderability JIS-C-5202 6.5 |
95% coverage MIN |
Test temperature of solder: 230± 5° C Dwell time in solder: 3± 0.5 SEC |
||||||||||||||
Nonflammability |
Nonflammable |
Load 5 min according to 5times, 10 times, 16 times rated power and A. C. respectively. |
Suppliers with verified business licenses